Based on the SIGMA Product Information for “Protein A-Immobilized” (adapted for SepCon from Column Method)
The necessary components:
1) Buffer A:
- 0.2M NaH2PO4 2.4g
- 0.15M NaCl 8.8g
- adjust to pH 8.0
2) Buffer B:
- 0.2M Na2HPO4 25.7ml
- 0.1M Citric Acid 24.3ml
- DI H2O 50.0ml
- adjust to pH 4 (for human IgG)
- adjust to pH 3 (we found that a pH of 4 doesn’t unbind IgG from beads; needs a lower pH)
3) Human IgG: reconstituted into 1mg/ml aliquots
4) Swollen Beads:
- literature: “One gram of powder [protein A beads] typically swells to 3-4ml of hydrated gel”
- In order to swell, though, one needs an excess of buffer A
- Add ~11ml of buffer A
- Let swell for at least 30 minutes at room temperature (we did ~4 hours)
5) A Transwell, to fit into the 24-well plate
Storage Note: The protein A beads must be stored in 20% ethanol (diluted from 100% concentration with buffer A)
Experiment in SepCon Format:
1) Rinse ethanol off of protein A beads (use ~20 CV)
- Spin down protein A beads (2 minutes at 1500 rpm)
- Aspirate.
- Add 7ml buffer A
- Shake
- Spin down (2 minutes at 1500 rpm)
- Aspirate.
2) Add IgG
- Transfer beads to 2ml centrifuge tube
- Add human IgG
- Mix
- Let sit in the refrigerator overnight, to allow plenty of binding time
3) Remove unbound IgG, until TECAN registers a neutral absorbance reading (~10CV)
- Spin down (2 minutes at 1500 rpm)
- Take 2×10μl samples (put into 96-well plate)
- Aspirate
- Add 1ml of buffer A; mix by flipping tube over several times.
- Spin down (2 minutes at 1500 rpm)
- Take 2×10μl samples
- Aspirate
- Add 1ml of buffer A; mix by flipping tube over several times.
- Spin down (2 minutes at 1500 rpm)
- Take 2×10μl samples
- Aspirate
- Add 1ml of buffer A; mix by flipping tube over several times.
- Spin down (2 minutes at 1500 rpm)
- Take 2×10μl samples
- Add 200μl of diluted bradford dye to each well
- Run TECAN absorption at 595nm
4) Set-up experiment in SepCon- to see if IgG unbinds from protein A beads and then diffuses up from the basolateral to the apical of the SepCon
[In the end, we want to keep volume at 1ml: 800μl in bottom, 200μl in top of SepCon, use basolateral to wet backside of membrane]
- Spin down beads (2 minutes at 1500 rpm)
- Aspirate
- Add 500μl of buffer B to centrifuge tube, mix well, put solution into bottom of the transwell (24-well plate)
- Add 300μl of buffer B to centrifuge tube, mix well, get the rest of the beads
- Wet back of membrane with buffer in basolateral
- Add 200μl of buffer B to apical
- Shake at 200 RPM for ~1 hour (tape down so plate doesn’t rattle)
5) After 1 hour, need to get beads back into a neutral solution (they can’t be at extreme pH’s for too long)
- Transfer SepCon to a neighboring well
- Transfer beads into the 2ml tube
- Spin down (2 minutes at 1500 rpm)
For solution:
- Transfer solution on top of beads back into the well
- Replace SepCon, let set-up sit at 0 RPM overnight
For beads:
- Use buffer A to transfer beads into a 15ml tube
- Wash with buffer A (~5ml)
- Store in 20% ethanol (8ml buffer A and 2ml 100% ethanol)
6) Get results
- Take 2×10μl samples each from the apical and basolateral of SepCon to see if IgG has diffused through the membrane.